INSTALLATION AND OPERATION
MANUAL
Freestanding Model
Advantage
Optima 3 FS *
FREESTANDING
AND INSERT
PELLET FIRED
STOVES
These appliances must be properly installed and operated in order to
prevent the possibility of a house fire. Please read this entire owner's
manual before installing and using your pellet stove. Failure to follow
these instructions could result in property damage, bodily injury or even
death. Contact your local building or fire officials to obtain a permit and
information on any installation requirements and inspection require-
ments in your area.
P/N 775097M, Rev. E, 12/03
Insert Model, Advantage Optima 3 INS not shown
* Shown with Decorative Log Option
RETAIN THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE
Freestanding Model
Advantage
Optima 2 FS *
Przeglądanie stron 0
1 2 3 4 5 6 ... 53 54

Podsumowanie treści

Strona 1 - INSTALLATION AND OPERATION

INSTALLATION AND OPERATION MANUAL Fre

Strona 2 - IMPORTANT WARNINGS

INSTALLATION PAGE 10 REMOVING APPLIANCE FROM PALLET 1. After removing the packaging from the stove, lift the hop-per lid, and remove all pre-package

Strona 3 - TABLE OF CONTENTS

INSTALLATION PAGE 11 INSTALLING SURROUND ASSEMBLY - Optima 3 INS (to be done after venting system is installed) The surround kit (purchased separatel

Strona 4 - PLANNING YOUR INSTALLATION

INSTALLATION PAGE 12 Optima 3 INS (Only) – Install damper rod knob as ex-plained on page 11. Adjustment Procedure: The damper knob should be pos

Strona 5

INSTALLATION THERMOSTAT INSTALLATION: NOTE: Always Disconnect Power Before Performing The Thermostat Installation. A 24 volt wall thermostat and 20

Strona 6

INSTALLTION PAGE 14 VENTING REQUIREMENTS It is recommended that only an authorized dealer install your pellet stove. The specified installation requi

Strona 7

INSTALLTION PAGE 15 VENT TERMINATION Do not terminate vent in an enclosed or semi-enclosed area such as: carports, garage, attic, crawl space, under

Strona 8

INSTALLATION PAGE 16 DETERMINING SIZE OF PIPE TO INSTALL To determine what diameter pipe to use in an installation (3” or 4”), first find the “equiv

Strona 9

INSTALLATION PAGE 17 INSTALLING YOUR FREESTANDING PELLET STOVE Standard Horizontal Vent Installation 1. Locate the proper position for the listed ty

Strona 10 - INSTALLATION

INSTALLATION Standard Horizontal Installation Configurations Note: Horizontal run of pipe requires 1/4” (7 mm) rise per foot. PAGE 18 Optima 3 FS C

Strona 11

INSTALLATION ♦ USA & Canada – Requires an approved noncombustible hearth or floor protector, 3/8” / (10 mm) millboard or equivalent (k = .84, r

Strona 12

IMPORTANT WARNINGS CAUTION: Read this manual thoroughly before starting installation. For your safety, follow the installation, op-eration and maint

Strona 13

INSTALLATION - Optima 3 INS Standard Installation Configurations Into and Existing Fireplace – Model: Optima 3 INS IMPORTANT- Make sure the chimney

Strona 14 - INSTALLTION

INSTALLATION INSTALLING OPTIMA 3 INS (CONTINUED) IMPORTANT- Make sure the chimney and firebox are clean and free of soot and ashes before installatio

Strona 15

CARE AND OPERATION PAGE 22 CONTROL BOARD OPERATION Stove On / Off Button – This button will turn your stove on or off while in Manual or Automat

Strona 16

CARE AND OPERATION PAGE 23 Note: The control board is equipped with an internal memory which will recall the last setting and mode the stove was

Strona 17

CARE AND OPERATION PAGE 24 Combustion Voltage Trim Steps: 1. Push button “twice” for access voltage calibration mode. 2. Identify the curren

Strona 18

CARE AND OPERATION PAGE 25 MANUAL OPERATION Pressing the stove on / off button initiates the start-up cycle. The green on / off light, near the

Strona 19

CARE AND OPERATION PAGE 26 DAMPER OPERATION (All models) The damper is a plate that helps control the amount of airflow supplied for combustion.

Strona 20 - INSTALLATION - Optima 3 INS

CARE AND OPERATION PAGE 27 FUEL Clinkering - Silica (or sand) in the fuel, along with other impurities, can cause clinkering. A clinker is a har

Strona 21

ROUTINE MAINTENANCE * Inspect your stove or insert at minimum frequency stated until you establish a minimum frequency required for your installation

Strona 22 - CARE AND OPERATION

ROUTINE MAINTENANCE PAGE 29 3. Release both ash pan latches and pull forward. Models Optima 2 FS and Optima 3 FS Model Optima 3 INS 4. Remove

Strona 23

TABLE OF CONTENTS PAGE 3 Important Warnings ... 2 Testing / Listing, EPA, Using this Manual...

Strona 24

ROUTINE MAINTENANCE PAGE 30 Pull Scraper Rod out & in several times REMOVABLE BAFFLE PLATES (All Models) At least once a year, the baffle pla

Strona 25

ROUTINE MAINTENANCE PAGE 31 Clean Photoeye Lens Remove Filter and Wipe Clean (Minimum frequency of 4 weeks - 6 months) CAUTION: If the filter

Strona 26

ROUTINE MAINTENANCE PAGE 32 DOOR ROPE GASKET (All Models) The condition of the rope gasket around the door and windows should be checked periodically

Strona 27

ROUTINE MAINTENANCE PAGE 33 SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B St

Strona 28 - ROUTINE MAINTENANCE

SPECIFICATIONS - Optima 2 FS PAGE 34 Flue Size 3” / 76mm Rear Width, Overall 23” / 584mm Depth, Overall 22 3/4” / 578mm Depth, Ove

Strona 29

SPECIFICATIONS - Optima 3 FS PAGE 35 Flue Size 3” / 76mm Rear Width, Overall 25 7/8” Depth, Overall 24 7/8” Depth, Overall w / 3” tee

Strona 30

SPECIFICATIONS - Optima 3 INS Note: Dimensions shown are approximations only (+/- ¼”) + Non-combustible floor protection must be used when installed

Strona 31 - Clean Photo

COMPONENT DEFINITIONS PAGE 37 AIR WASH To inhibit buildup of soot on the door glass, air is deliv-ered to the glass through an air wash system locate

Strona 32

WIRING DIAGRAM PAGE 38

Strona 33

TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 39 PROBLEM CAUSE(S) SOLUTIONS

Strona 34

PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc-ing fire hazar

Strona 35 - SPECIFICATIONS - Optima 3 FS

TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 40 PROBLEM CAUSE(S) SOLUTIONS

Strona 36 - Control

TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 41 Troubleshooting Notes for Q

Strona 37 - COMPONENT DEFINITIONS

REPLACEMENT PARTS LIST PAGE 42 Door Parts & Body Components Item # Part No. / Cat. No. Description Stove Model 2 14650460 Door Assembly, Cas

Strona 38 - WIRING DIAGRAM

REPLACEMENT PARTS LIST PAGE 43 Firebox Parts Item # Part # Description Stove Model 29 13640028 Clips, Brick Optima 2 FS 30 11750011 Clips, B

Strona 39 - PAGE 39

REPLACEMENT PARTS DIAGRAMS PAGE 44 56 81013 14 912 7 11

Strona 40 - PAGE 40

REPLACEMENT PARTS DIAGRAMS PAGE 45 15 16 17 192022 24 25 26 27 18 23

Strona 41

REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 3334 39 31 32 35

Strona 42 - REPLACEMENT PARTS LIST

REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42

Strona 43

OPTIONAL ACCESSORIES DIAGRAMS PAGE 48 Optional Accessories Item # Part # Model Description Stove Model 1 H0448 TKAO2-G Trim Kit, AO2 Gold Op

Strona 44

INSTALLATION TIPS PAGE 49

Strona 45 - REPLACEMENT PARTS DIAGRAMS

PLANNING YOUR INSTALLATION PAGE 5 FLOOR PROTECTION - Optima 2 FS This appliance requires noncombustible floor protec-tion. If the floor protection

Strona 46

SIMPLE OPERATING INSTRUCTIONS LABEL PAGE 50

Strona 47

SAFETY/LISTING LABEL – Model Optima 2 FS PAGE 51 Note that your stove’s serial number is printed on the safety label, which is located near the insid

Strona 48

SAFETY/LISTING LABEL – Model Optima 3 FS and Optima 3 INS PAGE 52 Note that your stove’s serial number is printed on the safety label, which is locat

Strona 49 - INSTALLATION TIPS

PAGE 53 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVI

Strona 50 - PAGE 50

1110 West Taft Avenue Orange, CA 92865

Strona 51

PLANNING YOUR INSTALLATION PAGE 6 FLOOR PROTECTION - Optima 3 FS The floor protector must meet or exceed the minimum thermal re-quirements as define

Strona 52

PLANNING YOUR INSTALLATION Clearances to combustibles are determined from testing to applicable standards for allow-able heat transfer. The clearance

Strona 53

PLANNING YOUR INSTALLATION PAGE 8 MASONRY AND FACTORY BUILT FIREPLACES The model Optima 3 INS is approved for installation into a solid fuel burning

Strona 54 - Orange, CA 92865

PLANNING YOUR INSTALLATION PAGE 9 Models – Optima 2 FS and Optima 3 FS MANUFACTURED (MOBILE) HOME INSTALLATION Freestanding Models – Optima 2